Products

Tracheostomy Tube

 
Tracheostomy Tube
 
£ÛPerformance, Structure and Components£İ: This product consists of tube body, obturator, tube connector, cuff, control valve, pilot balloon, inflation tube and inner cannula.
£ÛApplication£İ£ºFor clinical anaesthesia, artificial ventilation or other assisted ventilation.
 
Tracheostomy Tube
 [Function Description]£ºFor long time open airway condition use;
Connection to ventilator;
Soft low-pressure and high-volume cuff;
Various inner cannula sizes available;
Inner cannula is placed in the tracheostomy tube and can be cleaned and replaced at any time to maintain patient's airway clean and unobstructed.
 
Tracheostomy Tube
Specification
Size
PC04-100/800/060
ID6.0mm
PC04-100/800/065
ID6.5mm
PC04-100/800/070
ID7.0mm
PC04-100/800/075
ID7.5mm
PC04-100/800/080
ID8.0mm
PC04-100/800/085
ID8.5mm
PC04-100/800/090
ID9.0mm
PC04-100/800/095
ID9.5mm
PC04-100/800/100
ID10.0mm
Suctionaid Tracheostomy Tube
[ Function Description]£ºSpecial design of suction catheter facilitates the extraction of secretions on the cuff, significantly reducing the risk of aspiration pneumonia;
Various inner cannula sizes available;
Inner cannula is placed in the tracheostomy tube and can be cleaned and replaced at any time to maintain patient's airway clean and unobstructed.
 
Suctionaid Tracheostomy Tube
Specification
Size
PC04-100/860/060
ID6.0mm
PC04-100/860/065
ID6.5mm
PC04-100/860/070
ID7.0mm
PC04-100/860/075
ID7.5mm
PC04-100/860/080
ID8.0mm
PC04-100/860/085
ID8.5mm
PC04-100/860/090
ID9.0mm
PC04-100/860/095
ID9.5mm
PC04-100/860/100
ID10.0mm
 
£ÛOperation Instruction£İ£º
These instructions are intended for use with the following products£º
PC04-100/800/060-100
Tracheostomy tube, soft sealed cuff, size 6.0-10.0mm
PC04-100/860/060-100
Suctionaid tracheostomy tube, soft sealed cuff, size 6.0-10.0mm
Attention£º    1     Inner cannula is an optional accessory.
2 The use of an inner cannula reduces the airway diameter by 1.5mm (excluding size 6.0mm tracheostomy tube which reduces the airway diameter by 1.0mm)
 
[Description]£º
·         Smooth arc shaped design with tapered tip to assist placement and removal of both tracheostomy tube and smooth inner cannula with minimal disruption to patient's anatomy.
·         Thermosensitive materials with sufficient initial rigidity for insertion which then conforms to the individual patient's upper respiratory tract at body temperature ensuring minimum trauma.
·         15mm connector for connection to anaesthetic or ventilator breathing circuit is located on the tube (not the inner cannula).
·         Anatomically shaped flange for improved patient comfort and improved security of the tracheostomy tube.
·         New sealed cuff design with smooth transition to tracheostomy tube to improve ease of insertion.
·         A hollow obsturator with atraumatic tip for use with or without guide wire for improved ease of insertion. The obsturator retaining clips prevent obturator movement during insertion.
·         Inner cannula can be reusable. The "pulling ring'"makes it easy to insert/remove the inner cannula into/from tracheostomy tube.

PURECATH Medical (Shanghai) Co., Ltd.
Address£º2nd Floor, Building 6, 328 Jinglian Rd., Minhang District, Shanghai, P.R.China
Postcode: 201108
Tel: +86-21-64348830 Fax: +86-21-64348829